Skip to main content
Enhanced 5TWR7

Trane Priority 17 Heat Pump

Formerly XR17

SEER2
Up to 17.4
HSPF2
Up to 8.5
Compressor
Multi-Speed Inverter
Stages
Multi-Stage (6 speeds)
Trane Priority 17 Heat Pump outdoor unit
4.94 Google Rating
ROC Licensed
Same-Day Service
Family-Owned

The Trane Priority 17 (formerly the XR17) is our most-recommended heat pump for Phoenix homeowners. Its multi-speed inverter compressor is the key differentiator. Unlike traditional single-stage systems that are either fully on or fully off, the Priority 17 operates across 6 discrete speed stages, automatically selecting the lowest effective speed for current conditions. This means lower energy bills, better humidity control, more even temperatures, and significantly quieter operation.

We call this the "sweet spot" of the Trane lineup. It brings inverter compressor technology to a mid-range price point, delivering a meaningful upgrade in comfort and efficiency over single-stage systems without the premium cost of a fully variable-speed Premier system. When Trane introduced the multi-speed Priority 17, they discontinued the older two-stage XR16 because the multi-speed technology made it obsolete at a similar price point.

Key Features

Multi-Speed Inverter Compressor

Operates across 6 discrete speed stages, running at the lowest effective speed for current conditions. More nuanced than traditional two-stage, more affordable than fully variable-speed.

Spine Fin Outdoor Coil

Corrosion-resistant coil technology built for Arizona's dust, heat, and hard water conditions.

Better Humidity Control

Multi-speed operation runs longer cycles at reduced capacity, pulling more moisture from the air than short-cycling single-stage systems.

Noticeably Quieter

Lower speed stages run most of the time, making a real difference for bedrooms and outdoor living areas near the condenser.

Inverter Technology at a Mid-Range Price

Gets you into inverter-driven compressor technology without the premium price of a fully variable-speed system.

Full Specifications

SEER2 Up to 17.4
HSPF2 Up to 8.5
Compressor Multi-Speed Inverter
Stages Multi-Stage (6 speeds)
Sound Level As low as 68 dB
Warranty 12-Year Limited Parts
Refrigerant R-454B (A2L)
Sizes Available 2 Ton, 2.5 Ton, 3 Ton, 3.5 Ton, 4 Ton, 5 Ton
Model Numbers
5TWR7024A1000A5TWR7030A1000A5TWR7036A1000A5TWR7042A1000A5TWR7048A1000A5TWR7060A1000A
Legacy Model Prefix 4TWR7

Is This the Right System for You?

Ideal For

The Priority 17 is our top recommendation for homeowners who plan to stay in their home for 5+ years and want a meaningful upgrade in comfort and efficiency over a single-stage system. The multi-speed inverter compressor delivers noticeably quieter operation and better temperature consistency at a price point well below fully variable-speed systems. It's the best value in the Trane lineup for most Phoenix homes.

Consider an Alternative If

If budget is your absolute top priority and you're comfortable with the noise and on/off cycling of a single-stage system, the Choice 14 will cool your home reliably for less money. If you want the absolute peak in comfort, efficiency, and quiet operation - and are willing to invest for it - the Premier 18's variable-speed compressor takes performance to another level.

Pricing & Investment

The Priority 17 sits in the middle of the Trane lineup and represents what we consider the best overall value. The step up from a Choice 14 typically adds a moderate premium that most homeowners recoup through lower energy bills within 3-5 years. We provide free in-home estimates with full pricing transparency and offer financing options.

Warranty Coverage

The Priority 17 comes with a 12-year limited parts warranty when registered within 60 days - two years more than the Choice tier. TCS-installed systems are eligible for enhanced coverage. We also provide our lifetime workmanship warranty on the installation.

A2L Refrigerant Transition

Legacy model prefix: 4TWR7

Previously sold as the XR17 with model numbers starting with 4TWR7 (R-410A). The R-410A version used a traditional two-stage compressor. Current models (5TWR7) use R-454B refrigerant and feature an upgraded multi-speed inverter compressor with 6 stages, a significant improvement over the older two-stage design.

Frequently Asked Questions

Common questions about the Trane Priority 17 Heat Pump answered by our team.

Ask Us Directly
How much quieter is the Priority 17 than a single-stage system?

Noticeably quieter. The lower speed stages produce around 68 dB compared to 72+ dB for single-stage systems. Decibels are logarithmic, so each 3 dB reduction represents roughly a halving of perceived loudness. Since the Priority 17 runs at lower speeds most of the time, you hear the quieter setting the vast majority of the day.

What does multi-speed actually mean in practice?

The compressor has 6 discrete speed stages instead of the traditional on/off or low/high. On a typical 105F day, the system runs comfortably at one of the lower stages. Only on extreme heat days does it ramp up to full capacity. This means longer, gentler cooling cycles that distribute air more evenly and pull more humidity. It's a step beyond traditional two-stage technology but more affordable than fully variable-speed.

Is the Priority 17 the same as the old XR17?

The Priority 17 is the successor to the XR17, but with a significant upgrade. The old XR17 (4TWR7) used a traditional two-stage compressor. The current Priority 17 (5TWR7) uses a multi-speed inverter compressor with 6 stages and R-454B refrigerant. It's a better system at the same price tier.

Got a Quote for a 5TWR7?

Let us give you a second opinion. We'll make sure you're getting the right system at a fair price, with expert installation.